Installation and debugging of high energy igniter

Jan 06, 2020

Leave a message

High-energy igniters are widely used in the operations of thermal power plants and other industries and are very important equipment

1. Bolt fasteners for igniter are installed firmly horizontally or vertically;

2. The device should be grounded or connected to zero;

3. The nuts at both ends of the shielded cable are screwed to the output end of the igniter and the input end of the igniter respectively. The two ends must be tightened to closely fit the center electrode; if there is a gap between the electrodes, it will cause the center electrode to discharge and melt ;

4. The end of the electric nozzle of the ignition gun should extend into the densest part of the fuel zone; determine L according to the return flow of the burner and the injection angle of the oil gun, and the empirical value is 100-150mm;

5. After installation and commissioning of the device, the power supply should be able to fire reliably; when the power supply voltage is too low and the firing frequency is slow, adjust the transformer secondary output welding wire to increase the secondary voltage; when the power supply voltage is too high, the firing frequency When it is fast, adjust the secondary output welding wire of the transformer to reduce the secondary voltage.

Mastering the installation and debugging of high-energy igniters can make us more comfortable in normal use.