Technical requirements for ceramic ignition electrode assemblies for gas cookers
Apr 02, 2022
Leave a message
1 Main content and scope of application
This standard specifies the technical requirements, inspection methods and inspection rules for ceramic ignition electrode assemblies for gas cooking appliances.
3 Technical requirements
3.1 Dimension and tolerance requirements
Design requirements according to drawings.
3.2 Appearance quality
3.2.1 No cracking, no notch, no blistering, the surface glaze is uniform, and it is clean:
3.2.2 Ceramic without bending deformation:
3.2.3 The ignition electrode is not loose, deformed or notched:
3.2.4 The inorganic sealant and the seal should be evenly coated without foaming
4 Inspection methods
4.1 Salt water immersion test
Put the ceramic ignition electrode assembly into warm water with a concentration of 25%, soak it for 2 hours, and check whether the ceramic sleeve and the ignition electrode are corroded.
corrosion phenomenon. Check point ignition electrode for looseness.
42 Temperature resistance test
Put the ceramic ignition electrode assembly on an open flame and burn it for 1 hour, then take it out and cool it to room temperature, repeat 10 times, check the ignition electrode should be
No melting, no bursting of ceramic sleeves.
4.3 Endurance tensile test
Install the ceramic ignition electrode according to the state of use, and add 10kg pressure to the discharge end of the ignition electrode, (or add a pressure to the discharge end.
10kg tension) without loosening.
4.4 Torsional resistance test
Install the ceramic ignition electrode assembly according to the requirements of item 4.3, clamp the ignition electrode, apply a torque of 4N.m, and there is no loose phenomenon.
45
Impact resistance test
Place the ceramic ignition electrode assembly flat at a height of 0.8m and fall freely without breaking.
4.6
Withstand voltage performance test
Place the ceramic ignition electrode assembly flat on the grounding platform with the pulse generator, the discharge distance is 7mm, at the end of the ignition electrode
Input 15kV pulse voltage, the ceramic protective sleeve has no breakdown phenomenon, and the discharge distance between the tail end and the ground is three 7mm.
5 Inspection Rules
5.1 Appearance quality inspection:
5.2 Dimensions shall be inspected according to GB2828 Special Inspection Level 1.
6. Shipping, packing
6.1 When supplying, the parts and components must be packed in packaging and then packed in a turnover box in order for shipment. Where due to packaging, transportation and other reasons
The quality problem is the responsibility of the supplier.
6.2 The product model, component name, drawing number, quantity, weight, production date, manufacturer must be marked on the packing box.