About the maintenance of the flameout protection device of the gas stove:


1. Each burner has two needles, one is used for ignition, and the other is a safety device called thermocouple for flameout. The fire can burn it when you are lighting it. At this time, the thermocouple will conduct heat to a solenoid valve under the switch of the stove, the solenoid valve starts to work, the switch starts to ventilate, and the stove can work normally. If there is no response, it may be that the solenoid valve is broken, disassemble the panel, remove a white object connecting the two wires at the place where the size of the flame is adjusted, and replace it with a new one. The problem of automatic flameout is solved.

2. Check whether the connection of the solenoid valve is loose, that is, there is a wire connected to the switch on the stove head.

3. You can observe after the fire is on to see if the fire burns to the thermocouple. If not, check whether the fire outlet is blocked and pick it with a toothpick.

4. Lift up the gas stove and see if there is a gas outlet where the ignition is blocked. Poke with a thin wire.

5. Check if the induction needle is out of position, put the fire cover in place, and adjust the induction needle to align with the fire hole.

6. There is a foreign object between the induction needle and the grounding sleeve, let the induction needle touch the flame and clean up the dirt.

7. Check if the induction needle is broken and ask a professional to replace it.

8. If the battery is dead, you need to replace a battery.